Marknadens största urval
Snabb leverans

Fuse Protection against the Regenerative Circuit Internal Commutation Fault

Om Fuse Protection against the Regenerative Circuit Internal Commutation Fault

Current-limiting fuses are widely used to protect the thyristors in dc drive systems. In the event of the commutation failure when regenerating (inverting), the fuses need to interrupt in loop supplied by the ac and dc voltages acting in series which is the most difficult case for protection by fuse. In this paper, a detailed study of the complete interruption process has been investigated by modeling of arcing process of the fuse. The effect varying the motor time constant, supply impedance, number of fuses used to clear the fault and dc machine rating to the total response for fuses protecting against the regenerative circuit internal commutation fault has been studied. The model of 200A fuse is employed in this study and fuses in series with the semiconductor devices (F1) and fuses in ac line (F2) are both considered.

Visa mer
  • Språk:
  • Engelska
  • ISBN:
  • 9798211935136
  • Format:
  • Häftad
  • Sidor:
  • 24
  • Utgiven:
  • 6. oktober 2022
  • Mått:
  • 203x2x254 mm.
  • Vikt:
  • 78 g.
  I lager
Leveranstid: 4-7 vardagar
Förväntad leverans: 11. december 2024
Förlängd ångerrätt till 31. januari 2025

Beskrivning av Fuse Protection against the Regenerative Circuit Internal Commutation Fault

Current-limiting fuses are widely used to protect the thyristors in dc drive systems. In the event of the commutation failure when regenerating (inverting), the fuses need to interrupt in loop supplied by the ac and dc voltages acting in series which is the most difficult case for protection by fuse.
In this paper, a detailed study of the complete interruption process has been investigated by modeling of arcing process of the fuse. The effect varying the motor time constant, supply impedance, number of fuses used to clear the fault and dc machine rating to the total response for fuses protecting against the regenerative circuit internal commutation fault has been studied. The model of 200A fuse is employed in this study and fuses in series with the semiconductor devices (F1) and fuses in ac line (F2) are both considered.

Användarnas betyg av Fuse Protection against the Regenerative Circuit Internal Commutation Fault



Hitta liknande böcker
Boken Fuse Protection against the Regenerative Circuit Internal Commutation Fault finns i följande kategorier:

Gör som tusentals andra bokälskare

Prenumerera på vårt nyhetsbrev för att få fantastiska erbjudanden och inspiration för din nästa läsning.