Marknadens största urval
Snabb leverans

Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage

Om Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage

This excellently illustrated monograph summarizes the updated fresh information on the theoretical, practical, and rapidly extended facets of gamma correction 99mTc-hydroxymethylene diphosphonate pinhole bone scan (99mTc-GCPBS) to MRI, CR, and MDCT. Basically, 99mTc-GCPBS is able to precisely visualize and quantitate callused trabecular microfracture (CTMF) which is as little as 200 ¿m in size. The extended gamma correction images can very neatly demonstrate CTMF on MRI, conventional radiography (CR), and multidetector computed tomography (MDCT). Whenever appropriate, histological correlation is provided in conjunction with fine gamma corrected images. In this setting, ACDSee 10 gamma correction MRI and CR have been found to offer a highly useful option that deserves wider clinical interest. In practice, gamma correction MRI, CR, and MDCT can distinctly visualize CTMF so that CTMF can be precisely measured simply using an optic lens. By comparison, the naïve MRI, for example,shows CTMF which measures as big as 2 mm in size. Furthermore, 99mTc-GCPBS can now differentiate bone marrow edema from hemorrhage using the visuospatial mathematic method, which includes the ImageJ of the NIH.

Visa mer
  • Språk:
  • Engelska
  • ISBN:
  • 9789811544682
  • Format:
  • Häftad
  • Sidor:
  • 146
  • Utgiven:
  • 6. augusti 2021
  • Utgåva:
  • 12020
  • Mått:
  • 178x254x0 mm.
  • Vikt:
  • 388 g.
  Fri leverans
Leveranstid: Okänt - saknas för närvarande
Förlängd ångerrätt till 31. januari 2025

Beskrivning av Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage

This excellently illustrated monograph summarizes the updated fresh information on the theoretical, practical, and rapidly extended facets of gamma correction 99mTc-hydroxymethylene diphosphonate pinhole bone scan (99mTc-GCPBS) to MRI, CR, and MDCT. Basically, 99mTc-GCPBS is able to precisely visualize and quantitate callused trabecular microfracture (CTMF) which is as little as 200 ¿m in size. The extended gamma correction images can very neatly demonstrate CTMF on MRI, conventional radiography (CR), and multidetector computed tomography (MDCT). Whenever appropriate, histological correlation is provided in conjunction with fine gamma corrected images. In this setting, ACDSee 10 gamma correction MRI and CR have been found to offer a highly useful option that deserves wider clinical interest. In practice, gamma correction MRI, CR, and MDCT can distinctly visualize CTMF so that CTMF can be precisely measured simply using an optic lens. By comparison, the naïve MRI, for example,shows CTMF which measures as big as 2 mm in size. Furthermore, 99mTc-GCPBS can now differentiate bone marrow edema from hemorrhage using the visuospatial mathematic method, which includes the ImageJ of the NIH.

Användarnas betyg av Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage



Hitta liknande böcker
Boken Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage finns i följande kategorier:

Gör som tusentals andra bokälskare

Prenumerera på vårt nyhetsbrev för att få fantastiska erbjudanden och inspiration för din nästa läsning.