Marknadens största urval
Snabb leverans

Review of the Bureau of Reclamation's Corrosion Prevention Standards for Ductile Iron Pipe

Om Review of the Bureau of Reclamation's Corrosion Prevention Standards for Ductile Iron Pipe

"Ductile iron pipe (DIP) was introduced about 50 years ago as a more economical and better-performing product for water transmission and distribution. As with iron or steel pipes, DIP is subject to corrosion, the rate of which depends on the environment in which the pipe is placed. Corrosion mitigation protocols are employed to slow the corrosion process to an acceptable rate for the application. When to use corrosion mitigation systems, and which system, depends on the corrosivity of the soils in which the pipeline is buried. The Bureau of Reclamation's specification for DIP in highly corrosive soil has been contested by some as an overly stringent requirement, necessitating the pipe to be modified from its as-manufactured state and thereby adding unnecessary cost to a pipeline system. This book evaluates the specifications in question and presents findings and recommendations. Specifically, the authoring committee answers the following questions: Does polyethylene encasement with cathodic protection work on ductile iron pipe installed in highly corrosive soils? Will polyethylene encasement and cathodic protection reliably provide a minimum service life of 50 years? What possible alternative corrosion mitigation methods for DIP would provide a service life of 50 years?"--Publisher's description.

Visa mer
  • Språk:
  • Engelska
  • ISBN:
  • 9780309131636
  • Format:
  • Häftad
  • Sidor:
  • 186
  • Utgiven:
  • 1. november 2009
  • Mått:
  • 152x229x13 mm.
  Fri leverans
Leveranstid: Okänt - saknas för närvarande

Beskrivning av Review of the Bureau of Reclamation's Corrosion Prevention Standards for Ductile Iron Pipe

"Ductile iron pipe (DIP) was introduced about 50 years ago as a more economical and better-performing product for water transmission and distribution. As with iron or steel pipes, DIP is subject to corrosion, the rate of which depends on the environment in which the pipe is placed. Corrosion mitigation protocols are employed to slow the corrosion process to an acceptable rate for the application. When to use corrosion mitigation systems, and which system, depends on the corrosivity of the soils in which the pipeline is buried. The Bureau of Reclamation's specification for DIP in highly corrosive soil has been contested by some as an overly stringent requirement, necessitating the pipe to be modified from its as-manufactured state and thereby adding unnecessary cost to a pipeline system. This book evaluates the specifications in question and presents findings and recommendations. Specifically, the authoring committee answers the following questions: Does polyethylene encasement with cathodic protection work on ductile iron pipe installed in highly corrosive soils? Will polyethylene encasement and cathodic protection reliably provide a minimum service life of 50 years? What possible alternative corrosion mitigation methods for DIP would provide a service life of 50 years?"--Publisher's description.

Användarnas betyg av Review of the Bureau of Reclamation's Corrosion Prevention Standards for Ductile Iron Pipe



Hitta liknande böcker
Boken Review of the Bureau of Reclamation's Corrosion Prevention Standards for Ductile Iron Pipe finns i följande kategorier:

Gör som tusentals andra bokälskare

Prenumerera på vårt nyhetsbrev för att få fantastiska erbjudanden och inspiration för din nästa läsning.