Calculation of Critical Distance in Faulted Meshed Power System

Om Calculation of Critical Distance in Faulted Meshed Power System

Faults studies form an important part of power system analysis. The problem consists of determining bus voltages and line currents during various types of faults. If the fault location is known the problem can be easily solved. But if the fault location is unknown, it is difficult to solve the problem. If the fault location is known the problem can be easily solved. But if the fault location is unknown, it is difficult to solve the problem. There were attempts to find the critical distance of a fault that will cause certain per-defined voltage dip at certain bus, and the problem was easy to be solved in radial systems, but yet non of the existing researches could provide proper solution for finding the critical distance of the fault at certain line that will cause predefined voltage dip magnitude at certain bus in meshed power system. The paper provided proper solution based in Gauess Seidal to find the critical distance in meshed power system

Visa mer
  • Språk:
  • Engelska
  • ISBN:
  • 9798210632616
  • Format:
  • Häftad
  • Sidor:
  • 24
  • Utgiven:
  • 12. september 2022
  • Mått:
  • 203x2x254 mm.
  • Vikt:
  • 78 g.
Leveranstid: 2-4 veckor
Förväntad leverans: 30. december 2024
Förlängd ångerrätt till 31. januari 2025

Beskrivning av Calculation of Critical Distance in Faulted Meshed Power System

Faults studies form an important part of power system analysis. The problem consists of determining bus voltages and line currents during various types of faults. If the fault location is known the problem can be easily solved. But if the fault location is unknown, it is difficult to solve the problem. If the fault location is known the problem can be easily solved. But if the fault location is unknown, it is difficult to solve the problem.
There were attempts to find the critical distance of a fault that will cause certain per-defined voltage dip at certain bus, and the problem was easy to be solved in radial systems, but yet non of the existing researches could provide proper solution for finding the critical distance of the fault at certain line that will cause predefined voltage dip magnitude at certain bus in meshed power system.
The paper provided proper solution based in Gauess Seidal to find the critical distance in meshed power system

Användarnas betyg av Calculation of Critical Distance in Faulted Meshed Power System



Hitta liknande böcker
Boken Calculation of Critical Distance in Faulted Meshed Power System finns i följande kategorier:

Gör som tusentals andra bokälskare

Prenumerera på vårt nyhetsbrev för att få fantastiska erbjudanden och inspiration för din nästa läsning.